banner 去按钮
卖点
Five-Stage Filtration. Truly Clean Air.

The bottom-to-top airflow design allows heavier particles to settle before reaching the filters.
The remaining contaminants are then captured through a 5-stage filtration system,
ensuring clean, odor-free exhaust.

1.SS Protection
2.G4 Pre Filter
3.F8 Medium Filter
4.MOF Carbon + H11
5.H13 HEPA

SS Protection

Captures up to 99.9% of sparks, high-temperature particles, and oil mist.

G4 Pre-Filter

Captures coarse dust particles ≥ 5 μm with over 85% filtration efficiency.

F8 Medium Filter

Filters 1–5 μm dust and removes 85% of 0.3 μm particles.

MOF Carbon + H11

Adsorbs VOCs, odors, and gas-phase molecules. With H11 HEPA, no particles or odors escape.

H13 HEPA

Delivers 99.99% filtration efficiency at 0.3 μm, capturing ultra-fine dust, smoke, and aerosols.
Deep Odor & VOC Removal That Protects
What You Breathe

Advanced MOF-derived carbon captures odors and VOCs more efficiently, delivering faster odor removal
and longer-lasting protection against harmful gases.

Standard Honeycomb Structure
Thunder Air MOF Structure

Note: All structures shown are conceptual illustrations for visualization

Built for Continuous Production

Handles continuous use. Lasts far longer than hobby fume extractors.

Up to 3x Longer Service Life
Thunder Air
Protected by SS, G4 & F8 Layers
Hobby Standard
System
Frequent Replacement
对比 17
Lasts Longer, Costs Less.
净化机2 16 拷贝
Top-Mounted Fan
for Stronger Performance

Space Efficiency

Top placement frees the entire bottom chassis for massive dust collection capacity.

Noise Reduction

Optimized structure reduces noise by >5 dB compared to bottom-fan models.

Stability

Low center of gravity design ensures <10% vibration amplitude.

Airflow Efficiency

Zero reverse resistance. Efficiency increased by 15%.

Top Mounted Fan for Stronger Performance
Power That Stays Strong Over Time

Thunder Air delivers up to 700 m³/h airflow and 4000 Pa of static pressure even under continuous,
heavy-duty use–no drop in suction, no performance fade.

42e141e3 5bf0 41e7 a623 051a8790e111 拷贝 2
Smart Filter Monitoring
Made Maintenance Easier

The Thunder Air-700 is equipped with a real-time intelligent
monitoring system that tracks filter usage via a differential
pressure sensor. Users can easily see the percentage of the
filter already used and its current status directly on the control
panel, making maintenance quick and hassle-free.

Smart Filter Monitoring Made Maintenance Easier
Not Just Powerful - Industrial Safe
40 Layer Fire Defense

Fully Sealed Structure

The metal housing is fully sealed, covering every potential leak point, including interfaces and duct connections. This ensures exhaust escape is reduced to below 0.01%, keeping the workspace safe and clean.

Fully Sealed Structure

40-Layer Fire Defense

The 40-layer wave-shaped structure delivers 99.99% fire protection and 200% coverage area, while reducing airflow resistance by 12%. It prevents sparks and high-temperature particles from igniting the filtration system.

Particle Free Odor Free

Particle-Free & Odor-Free

With H13 HEPA and MOF carbon, the exhaust is free of fine particles and VOC odors. Even the toughest pollutants are captured before they can escape.

Easy to Use, Built for Convenience
Low Noise, High Comfort
Low Noise, High Comfort
手拉 拷贝
Tool-free Filter Replacement
Quality Wheels
Quality Wheels
Bottom Debris Collection Tray
Bottom Debris Collection Tray
Versatile Air Protection
for Every Workplace

Thunder Air fume extractor is engineered for versatile
use across a wide range of industrial and commercial
environments, including

Laser Processing
Technical Specifications
Product Thunder Air 700
Dimensions 475x605x1003 mm/ 18.70" x 23.82"x 39.49"
Airflow MAX.700 m³/ h / 412 cfm
Air Pressure MAX.4000 Pa
Compatible Voltage 220 V
Noise Level <65 dB
Weight 95 kg / 209.44 lb
Power 600 W
Airflow Adjustment 5 Levels
Touch Screen 7" Touchscreen
Air Duct Ø100 mm (Standard), 150 mm, 200 mm (Optional)
Control Mode PLC-controlled speed regulation and differential pressure signal alarm
5-stage Filter System
  • SS Protection — 99.99% fire protection
  • G4 Pre-Filter —≥85% efficiency (≥5 μm)
  • F8 Medium Filter —≥85% efficiency(0.3 μm)
  • MOF Carbon + H11 — Gas-phase molecules & VOC adsorption
  • H13 HEPA — 99.99% efficiency (0.3 μm)
FAQs About Thunder Air
1. Do I need a Thunder Air fume extractor?

If your workspace generates dust, fumes, odors, or airborne particles that affect air quality, equipment performance, or employee safety, a dedicated air filtration system like Thunder Air is highly recommended. It helps maintain a clean working environment, reduce health risks, and protect sensitive equipment from contamination.

2. Is Thunder Air worth the investment?

Thunder Air is built for long-term reliability and low maintenance costs. With durable multi-stage filters, intelligent monitoring, and industrial-grade construction, it reduces downtime, extends filter life, and lowers total cost of ownership. For professional environments that value safety, stability, and consistent air quality, it is a cost-effective long-term solution.

3. What environments is Thunder Air suitable for?

Thunder Air is designed for a wide range of professional environments, including workshops, studios, factories, laboratories, and educational facilities. It effectively handles dust, fumes, and odors generated during various production processes, making it a versatile solution for both light-duty and industrial applications.

4. Which Thunder Laser machines are compatible with Thunder Air?

Thunder Air is compatible with the following Thunder Laser machines:

(1)Bolt Series, including Thunder Bolt, Thunder Bolt Plus, Thunder Bolt Pro 22, Thunder Bolt Pro 32 and Thunder Bolt Pro 36;

(2)Nova Series, including Nova 24 and Nova 35;

(3)Nova Plus Series, including Nova Plus 24 and Nova Plus 35;

(4)Titan Series, including Titan 27, Titan 35, Titan Pro 27 and Titan Pro 35

(5)Aurora Series, including Aurora Lite / Aurora UV / Aurora MOPA / Aurora Fiber

5. How often do I need to replace the filters of my Thunder Air?

The maintenance schedule varies for each filtration layer:

The pre-protection unit, which blocks large particles, oil, and sparks, should be cleaned roughly every 30 days to maintain peak performance.

The pre-filter typically requires replacement every 3 to 6 months, while the medium filter can last 6 to 12 months depending on usage.

The activated carbon layer, responsible for adsorbing fumes and odors, generally needs replacing every 3 to 6 months, although it may appear saturated sooner in heavy-use environments.

The high-efficiency HEPA filter provides long-term protection and usually lasts between 12 and 18 months.

Thunder Air’s intelligent monitoring system will notify you when any layer requires attention, ensuring consistent air quality and reliable operation.

6. How loud is Thunder Air during operation?

Thunder Air is designed for quiet operation, with a maximum noise level of just 65 dB. This allows it to deliver powerful air extraction while maintaining a comfortable working environment for workshops, studios, and professional facilities.

7. How do I know when maintenance or filter replacement is needed?

Thunder Air features an intelligent filter monitoring system that tracks filter status in real time. The control panel provides clear visual indicators to notify users when maintenance or replacement is required, ensuring consistent performance and hassle-free operation.

8. Is Thunder Air easy to install and use?

Yes. Thunder Air is designed for plug-and-play installation and simple operation. No complex setup is required—just power on and start using the system immediately.

Get Your Thunder Air Today

Experience long-term reliable filtration
and a safer working environment.

    ————————
    Download popup form

    America

    Europe

    Aisa

    Oceanica

    Africa